Features of the X-10

Filter:
 
Transmission pulse signals of high frequency (120 KHz.) Through the electricity network is affected by interference from other devices (motors, intercoms plugged into the network, reactors ...) or other facilities of the type X-10 coming home. It is therefore essential to use the filter that isolates the installation to be controlled with common carriers, of the shocks themselves (washing machine, dishwasher, fridge ...) and outside the home.
The filter also prevents our signals of 120 Khz. can go abroad and disturb other facilities.
The blocking filter must be placed immediately after the differential and before the pious individual protection. It is mounted by inserting it into the DIN rail and has the following terminals:
L: input from the differential phaseN: entry for the neutralL: output stage circuit for magnetothermic
Three-phase filters are coupled by connecting its terminals K to the next stage.
Lamp Module Wall Switch (incandescent lamps only)
It replaces the conventional switches on, off and regular incandescent lamps.
Switch: shortRegulator: long press
It is a receiver that is controlled locally and remotely from conventional push from any X-10 controller. switched facilities with conventional switches connecting them to terminal 2.
Answer the following instructions:
A-Light-all general instructions on-(all lights on)
                                          
- All units of f-(all lights off)
B-individual statements-on-(on)
                                              
- Off-(off)
                                              
Albright-(increase intensity)
                                              
- Dim-(lower intensity)
Power supply: 220 V/50 HzPower: 60 to 500 W (incandescent lamps only)


Note: This module is not used to control inductive loads such as fluorescent lights, fans, etc., only serves to incandescent lamps. For inductive loads were used "appliance modules"
Appliance module wall switch (you can connect both devices "motors, fluorescent ..." as lamps)
Replacing conventional switches for control (on and off) of fluorescent or appliances with a load greater than 10 th. Can also be used to control incandescent lamps
 

Is a receiver that is controlled locally and remotely from conventional push from any X-10.The driver switched facilities combined with conventional push the market connecting to terminal 2
This module is used to create scenes of fluorescent lighting in living rooms, dining rooms, libraries ... or to control appliances such as air conditioning, fans, coffee maker, washing machine, etc.
Supply: 220V/50 HzPower: 2000 W (incandescent lamps only) or 10 A
Lamp module for DIN rail (incandescent lamps only)
 

It is an X-10 receptor whose function is to remotely control a lighting circuit (on, off and regulation). It can be activated or controlled with push buttons at terminal 2, with the driver or the adapter module alarms
It is designed to operate with 220V lamps, including halogen 12V and 24V. The special circuitry contains permits. It can provide power 40 to 700W in incandescent lamps. When using this module with low voltage lights, the transformer must be located such lights as if it were the lamp.
 

Module for DIN rail device (both devices such as lamps)
 
It is a remotely controlled relay. DIN rail mounted in the electrical box, rules on and off the power circuit which is connected (washing machine, dishwasher, electric heating, garden lighting) to a power of 2000W or 9 A in incandescent lamps, or 3 A in engines. In switched facilities are combined with conventional market switches connected to terminal number 2. You can also send a switch connected to terminal number 1
 

You can also send X-10 controller and the remote control and universal module or adapter alarms. When the module is running a red LED lights. It has a 3 position switch:
 

Position 1: the connected load will not be turned on and off from other elements

Position 2: the connected load will remain off and not be turned on from another devicePosition auto: the connected load can be controlled by any of the controls.
Terminal 1 of the module is designed to connect the switches. The relay module is activated when voltage and turns off when no voltage at terminal
Terminal 2 of the module is designed to push buttons. Each time voltage is applied changes state


Adapter module alarms or universal module

It is activated by closing a normally open without tension and sends a message to enable the modules in 3 ways: 2 alarm modes and a form for automatic
It features the following controls:
The "test": simulates the contact closureThe button "all units off": Turn off all modules with the same adapter codeThe switch "imput": select two configurations: position (A) and position (B).- Position (A): allows connection of low voltage (6-8 V)- Position (B) allows the closure of a volt free contact
The selector "mode": selects the three connection modes (1-2-3)
• Mode 1 (alarm): turns all lamp modules in the same house code of the adapter and any other module (the device) in the same house code and number 

When the alarm is reset (deactivated): Lighting modules remain lit. The module set in the same house code and unit (stereo) turns off.
• Mode 2 (alarm): all lighting modules with the same house code flash adapterWhen disabled: lamp modules and wall plug, stay on. Rail modules are turned off.
• Mode 3 (automatic switching) illuminates any module set to the same house and unit code of the adapter.
When turned off, turn it off.
In modes 1 and 2, the lights stay on when the alarm disappears as an indication of being activated.


You can connect the adapter to a contact alarm magnetic door or window: to open the door or window, would go on all the lights flashing or permanently ... and the stereo

Driver / receiver IR

Emitting element is a power line, plugged into any electrical outlet provides global control over the rest of the X-10 components of the system: receptors on and off, dimming, blind control. It also includes an IR receiver so it can be used with the remote control.
Turns on and off and control the light level up to 8 electrical or incandescent lights (for each house code) from the keyboard itself. It also allows the reception of infrared signals from remote controls to the X-10.
(A total of 128 rule allows groups of modules, 8 for each house code: 8 x 16 = 128)
Operation:
A. - Plug the controller into any wall installation2. - Set the house code with the same letter as the other X-10 modules to be controlled.3. - Set the selector for the group you want to control modules (modules 1-4 or 5-8)
Control lights and appliances from the keyboard
1 Turn on or turn off a module
   
a) pressing the button Unit Code (1,2,3,4 / 5,6,7,8)
   
b) pressing the appropriate ON / OFF button to turn on or off
2 Regular light intensity
    
a) pressing the button Unit Code
    
b) press the BRIGHT DIM to reduce or to increase the intensity (hold the button until the desired level)
3 To turn on all lights controlled by X-10 modules, presented in the same house code:
    
- Press the ALL LIGHTS ON .......
    
This option affects all 16 unit codes, not only at 1-4 or 5-8
4 To turn off all modules X-10 (both lights and appliances) that are configured with the same house code.
     
- Press the ALL UNITS OFF ......


Module built blinds

It is a switch that is controlled locally or remotely via X-10.Se controller used to control motorized blinds, shades or awnings. The order may be:
ON .................... fully openCompletely closed off ...................BRIGHT or DIM half open .....
Leaving the house, with a single button, you can download all the blinds. Using the PC + ACTIVE HOME SOFTWARE, which allows for "simulation face" to be able to schedule the opening and closing blinds and curtains